PITLANE.

Motor Lab

Peak-family v1 · choose the estimation method below

Motor RPM from sound

Motor

Choose a motor to start

Recommended trial when the dominant peak swaps: Analyse peak family. Requires an observed base, never invents a missing base; validate with a tachometer.

Experimental RPM · assumed 1 cycle(s)/rev · uncalibratedIdle
— RPMNot measuring

Tracked acoustic peak — Hz · Elapsed — · Scale 0–40,000

Press start to measure. Microphone never starts automatically.

RMS — dBFS · Clipping: — · digital level, NOT dBA

Experimental RPM = Hz ×60/1 · assumed 1 cycles/rev, NOT identified harmonics

Changing this stops capture and clears the current run; press Start again. Order 3 is a hypothesis to compare with a reference instrument, not a motor-specific fact.

Peak RPM—
Average RPM—
Eligible0

Current run, eligible points only · Average = sample mean

Start → wait for Ready → run motor · saves on return to quiet

Automatic detection inactive

RPM over time

No live measurement

RPM020400.00.51.0Elapsed time (s)No eligible values yet
● Per-frame values (unsmoothed)┄ Average◆ Peak▏Rejected

Tap the chart, or focus it and use the arrow keys

RPM uses each row’s own calibration only

PEAK—
AVG—
MIN—
0 valid RPM · AVG = sample mean of eligible points, not time-weighted

Trend and statistics appear once the frequency settles.

Raw data (0 records)

“Raw data” = per-frame measurement records before any display smoothing, NOT raw microphone PCM samples · RPM is derived from acoustic frequency · rejected rows stay visible with a reason and “—”.

History stays in this page · reload clears it · CSV only on click

Motor sound

Digital level · not dBA

No spectrum yet · — ·

100 Hz20504000 Hz

Horizontal: Hz · Vertical: max-held FFT level per column, uncalibrated, NOT SPL/dBA · acoustic peaks are not shaft speed

· Bin spacing is not accuracy or order identification

Advanced settings & details

RPM calculation

Choose estimation mode and manual order beside the gauge above. No automatic model switching.

EXPERIMENTAL: default hypothesis is 1 acoustic cycle/revolution; RPM = Hz ×60. Acoustic order/harmonics are NOT identified, so errors can be multiples. This is NOT measured or calibrated RPM. Motor identity supplies no factor or catalog RPM.

TI documents 6 ELECTRICAL current ripples/rev for 2 brushes / 3 commutator segments. It does NOT prove the microphone peak has that order. Alternatives 1/3/6 expose ambiguity, not automatic identification. Validate with a tachometer. TI SLVAFO8A

Conditional RPM candidates, NOT confirmed: 1/rev → — · 3/rev → — · 6/rev → — · selected 1/rev

Start the microphone BEFORE running the motor. Wait 1.5 seconds for the ambient baseline, then run the motor. Derived values collect as soon as frames arrive. After 2 seconds of audible activity followed by 2 seconds of quiet, automatically save the result and stop the microphone. Quiet does NOT prove the shaft stopped.

Frequency search band

Hz, NOT an RPM range. Changing the band stops capture and clears calibration. The dominant peak may be a harmonic, not the rotation frequency.

Stability: last 10 frames vary ≤1%, without clipping or another peak within 6 dB. This does not certify correct harmonic selection.

Calibrate RPM with a reference

Use a trusted tachometer on the same motor and setup. Freeze Hz while reading reference RPM. Clear and recalibrate after changing motor, voltage, load, mic placement or tracked peak.

Frozen reference Hz: —

Uses “Test conditions” in the motor card above · editing it clears calibration

Not calibrated: RPM stays —. Calibration is not retained across stops or navigation.

This ratio only applies to the same tracked acoustic feature. A harmonic change can multiply the error. Validate against a tachometer at multiple speeds before trusting RPM.

Signal diagnostics

RMS — dBFS · uncalibrated digital level, NOT dBA · baseline — dBFS

Heuristic: baseline ≤ −40 dBFS and range ≤ 8 dB; activity ≥ baseline +12 dB and ≥ −65 dBFS with steady Hz; quiet ≤ baseline +6 dB. Clipping, competing peaks or frame gaps are not quiet. Stop cancels; manual save/end remains available.

Microphone off · no live RPM

Observed acoustic peaks (NOT shaft speeds): —
Near-integer frequency pairs (do NOT identify harmonic/fundamental): —

Peak / median spectral floor contrast: — dB · not accuracy or calibrated SNR

FFT 16384 · ~10 updates/s

Requires a recent steady microphone reading (within 1.5 seconds) calibrated with a tachometer for this motor, setup and session. Hz and self-test cannot transfer.

Data and safe testing

  • Audio stays in browser memory; no audio files, MediaRecorder or audio / measurement API uploads.
  • Mobile Safari/Chrome need Web Audio, mic permission and HTTPS. 127.0.0.1 on your phone means the phone, not your Mac; a Mac LAN HTTP IP normally cannot use microphone capture.
  • Echo cancellation / noise suppression / auto gain are requested off where supported. Browser / OS may still process audio; this is not a calibrated instrument.
  • Secure the unloaded motor, away from moving gears / wheels. Follow manufacturer power limits. Avoid rotating parts, heat and water. This tool does not control power or hardware.
  • Tab hide, screen lock or navigation stops listening; restart explicitly. Synthetic tests do not validate the microphone, physical phone or RPM accuracy.

Choose a motor to start